■□■Advantages■□■ ■ By optimizing the emitter control and detector circuit, the longevity and long-term stability of the IR cell are achieved. ■ The S/C/SC832 standard model is equipped with one wide-range IR detector for carbon and sulfur analysis, simplifying calibration and condition setting. ■ The optional S/SC832DR model is equipped with two IR detectors for sulfur analysis, suitable for a wide range of analysis from trace to high concentration. ■ Analysis range SC832: 0.008mg to 30mg (0.004% to 15%) ■ Analysis accuracy S: Standard deviation (s) 0.004mg or RSD 1% * whichever is larger C: Standard deviation (s) 0.0088mg or RSD 1% * whichever is larger ■ Analysis time: 60 to 120 seconds (typically) ■ Sample weight: Typically sulfur only: 350mg (coal), carbon & sulfur: 200mg (coal) ■ Detection method: Non-dispersive infrared absorption method ■ Furnace type: Resistance heating furnace 800℃ to 1550℃ (set value ±10℃) ■ For more details, please contact us. ■□■Uses■□■ Coal, coke, cement, petroleum products, ores, soil, catalysts, rubber, etc.
---

---

---
  1. Featured Products
    Sulfur Carbon Analyzer Model SC832Sulfur Carbon Analyzer Model SC832
    overview
    ■□■Advantages■□■ ■ By optimizing the emitter control and detector circuit, the longevity and long-term stability of the IR cell are achieved. ■ The S/C/SC832 standard model is equipped with one wide-range IR detector for carbon and sulfur analysis, simplifying calibration and condition setting. ■ The optional S/SC832DR model is equipped with two IR detectors for sulfur analysis, suitable for a wide range of analysis from trace to high concentration. ■ Analysis range SC832: 0.008mg to 30mg (0.004% to 15%) ■ Analysis accuracy S: Standard deviation (s) 0.004mg or RSD 1% * whichever is larger C: Standard deviation (s) 0.0088mg or RSD 1% * whichever is larger ■ Analysis time: 60 to 120 seconds (typically) ■ Sample weight: Typically sulfur only: 350mg (coal), carbon & sulfur: 200mg (coal) ■ Detection method: Non-dispersive infrared absorption method ■ Furnace type: Resistance heating furnace 800℃ to 1550℃ (set value ±10℃) ■ For more details, please contact us.
    Application/Performance example
    ■□■Uses■□■ Coal, coke, cement, petroleum products, ores, soil, catalysts, rubber, etc.