Carbon Analyzer - Company Ranking(1 companyies in total)
Last Updated: Aggregation Period:〜
This ranking is based on the number of page views on our site.
Display Company Information
Company Name | Featured Products | ||
---|---|---|---|
Product Image, Product Name, Price Range | overview | Application/Performance example | |
■□■Advantages■□■ ■ By optimizing the emitter control and detector circuit, the longevity and long-term stability of the IR cell are achieved. ■ The S/C/SC832 standard model is equipped with one wide-range IR detector for carbon and sulfur analysis, simplifying calibration and condition setting. ■ The optional S/SC832DR model is equipped with two IR detectors for sulfur analysis, suitable for a wide range of analysis from trace to high concentration. ■ Analysis range SC832: 0.008mg to 30mg (0.004% to 15%) ■ Analysis accuracy S: Standard deviation (s) 0.004mg or RSD 1% * whichever is larger C: Standard deviation (s) 0.0088mg or RSD 1% * whichever is larger ■ Analysis time: 60 to 120 seconds (typically) ■ Sample weight: Typically sulfur only: 350mg (coal), carbon & sulfur: 200mg (coal) ■ Detection method: Non-dispersive infrared absorption method ■ Furnace type: Resistance heating furnace 800℃ to 1550℃ (set value ±10℃) ■ For more details, please contact us. | ■□■Uses■□■ Coal, coke, cement, petroleum products, ores, soil, catalysts, rubber, etc. | ||
---
--- |
--- |
-
- Featured Products
-
Sulfur Carbon Analyzer Model SC832
- overview
- ■□■Advantages■□■ ■ By optimizing the emitter control and detector circuit, the longevity and long-term stability of the IR cell are achieved. ■ The S/C/SC832 standard model is equipped with one wide-range IR detector for carbon and sulfur analysis, simplifying calibration and condition setting. ■ The optional S/SC832DR model is equipped with two IR detectors for sulfur analysis, suitable for a wide range of analysis from trace to high concentration. ■ Analysis range SC832: 0.008mg to 30mg (0.004% to 15%) ■ Analysis accuracy S: Standard deviation (s) 0.004mg or RSD 1% * whichever is larger C: Standard deviation (s) 0.0088mg or RSD 1% * whichever is larger ■ Analysis time: 60 to 120 seconds (typically) ■ Sample weight: Typically sulfur only: 350mg (coal), carbon & sulfur: 200mg (coal) ■ Detection method: Non-dispersive infrared absorption method ■ Furnace type: Resistance heating furnace 800℃ to 1550℃ (set value ±10℃) ■ For more details, please contact us.
- Application/Performance example
- ■□■Uses■□■ Coal, coke, cement, petroleum products, ores, soil, catalysts, rubber, etc.
-
Membership (free) is required to view all content.
Already a Member? Log In Here